3-10 Service Manual
4400-001
Set TX Level
Default=12 dBm
FCC requires that the transmission level be less than -9 dBm. From -
9 dBm to -15 dBm is acceptable. You can set the transmission level
between 0 and -15 dBm in 1 dBm steps using the operator panel
keypad. Accuracy is +0/-3 dBm.
1. Press Setup.
2. Press Menu until ‘Set TX Level’ displays.
3. Enter a number from 1 through 15 on the keypad.
Set RX Level
Default=-43 dBm
Reception level may be too low due cable losses. If set to -43 dBm,
reception sensitivity will be between 0 and -43 dBm.
1. Press Setup.
2. Press Menu until ‘Set RX Level’ displays.
3. Enter a number from 40 through 50 on the keypad.
Pause Time
Default=3 seconds
This sets the length of the pause time from 1 through 9 seconds.
1. Press Setup.
2. Press Menu until ‘Pause Time’ displays.
3. Enter a number from 1 through 9 on the keypad.