EasyManua.ls Logo

LEYBOLD SCREWLINE SP 630 F - Purge Gas Facility and Supplied Equipment; Purge Gas Facility Data and Supplied Items

LEYBOLD SCREWLINE SP 630 F
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
29GA02411_002_C0 - 10/2016 - © Leybold
1.2.4 Technical Data of the Purge Gas Facility
(only for certain pump versions, see Section 1.4)
Connection thread/gas supply G 1/8 - inside thread
Operating pressure 3 - 10 bar (g)
Media temperature +10 °C to + 40 °C
Operating medium Filtered, dry air or nitrogen
of the quality class 5,
free of oil, quality class 3 in accordance
with ISO 8573-1
Filter mesh 40 µm
Operating voltage/valve 24 V DC +10 % / -20%
normally closed
Power 2.5 W
Maximum power consumption 3.4 W
Protection type IP 65 in accordance with IEC 60259
Cable diameter < 6.5 mm
Purge gas pressure/system pressure
to be set up 2.5 bar
Purge gas volume flow 20 Std. l/min
1.3 Supplied Equipment
The SP 630/SP 630 F is supplied ready for installation and connection.
The pump is delivered with:
An integrated 15 kW motor.
Installed SP-Guard with 20 meter connection cable.
The required amount of gear oil (is supplied separately).
An intake screen preventing the ingress of small objects into the inlet of the
pump.
1 crane eye for transporting the pump.
Cable fitting M32 x 1.5 for D = 11 - 21 mm
Blank stopper M16 x 1.5
Blank stopper M40 x 1.5
Square key for disassembly/assembly of the cover and for opening the fan
housing.
Operating Instructions
Intake and discharge ports are sealed with foil. Remove this foil and also the
desiccant inside before switching on the pump.
For the purpose of shipping the pump, the pump has been affixed to a spe-
cial pallet. Retain this pallet in case the pump needs to be returned.

Table of Contents

Related product manuals