EasyManua.ls Logo

LEYBOLD SCREWLINE SP 630 F - System Block Diagram and SP-Guard Connection

LEYBOLD SCREWLINE SP 630 F
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
50 GA02411_002_C0 - 10/2016 - © Leybold
Ölstand-
schalter
Vibrations-
sensor
Öltemperatur-
sensor
Auslassdruck-
schalter
SP - Guard
M
3
>>
>>
>>
Netzteil
SPSA / D
24 V DC
80 W Anzug
6 W Betrieb
24 V DC
2,5 W
max. 3,4 W
Schraubenpumpe
Kundenseitige
Installation
Gasballast
Sperrgas
230 V AC
L
24 V DC
F 2
F 1
L 2
L 1
L 3
p
=
Fig. 3.5 Block diagram for the screw pump with accessories
Customer
installation
PLC
PSU
Screw pump
Vibration
sensor
Exhaust
pressure switch
Oil level
switch
Oil tempera ture
sensor
24 V DC
80 W actuation
6 W operation
24 V DC
2.5 W
max. 3.4 W
Gas ballast
only 117 019/
105/106/115/116
Purge gas
only 117 017-019/
and 117 113-116

Table of Contents

Related product manuals