TRIVAC D 40 L,
TRIVAC D 63 L,
TRIVAC D 90 L
Measurement / Test quantity
Operation / Auxiliary materials
Interval Remarks
Check the fan of the motor as well as the
cooling
ns on the motor for deposits,
and clean as required.
Brush and industrial vacuum cleaner. Annually*
Clean befor
e the maintenance interval has elapsed when
the pump or the motor gets too warm.
Caution: Switch off the pump and make sure that it does
not run inadvertently (disconnect from the mains).Refer to
Clean the motor cooling fan on page 49.
* For normal applications, the maintenance interval is 1 year or 6000 hours.
The recommendation above is only for pumps running in normal applications. In case of running in medium and harsh applications, the maintenance interval needs to be shortened
according to application requirements.
If other type of oil is used for the pump, the maintenance interval needs to be adjusted accor
dingly.
We recommend that you service the pump every three years covering the following:
Cleaning
Checking the individual components
Exchange of all seals
Functional check.
This service must be run by the our Service.