Table 3 Electrical data (three‑phase motors)
Pump
Nominal supply (V) Frequency (Hz) Power (kW) Product number
TRIVAC D 40 L,
LVO 130
220/230/380/400 50 1.1 1019040V00
220/230/380/400/415 50 1.1
1019040V01
230/460 60 1.3
200 50
1.5 1019040V02
200/380 60
TRIVAC D 63 L,
LVO 130
220/230/380/400 50 1.5 1019063V00
220/230/380/400/415 50 1.5
1019063V01
230/460 60 1.8
200 50
2.2 1019063V02
200/380 60
TRIVAC D 90 L,
LVO 130
220/230/380/400 50 2.2 1019090V00
220/230/380/400/415 50 2.2
1019090V01
230/460 60 2.6
200 50 3.0
1019090V02
200/380 60 3.0
4.2 Performance curves
Figure 5. Pumping speed curve - TRIVAC D 40 L
21
300956027_002_A0 - 03/2022 - © Leybold
Technical data