EasyManua.ls Logo

LG 26LD350 - Page 14

LG 26LD350
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 14 -
LGE Internal Use OnlyCopyright © 2010 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
G” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
4.7. Internal pressure
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-ZA) or Serial
number like photo.
CMD LENGTH ADH ADL DATA_1 . . . Data_n CS DELAY
No. Adjust mode CMD(hex) LENGTH(hex
)
Description
1
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
Row Li ne
Column Line
CLC
CST
Pane l
S
Y
S
T
E
M
Gat e Driv e IC
So urce D r i v e I C
Circuit Block
Ti m i n g
Co nt r oll er
Po w e r
Blo ck
V
COM
Ga mma
Re f e r ence V oltage
Gamm a R eference
Volta ge
Data (R,G,B ) & C ont ro l s ignal
Control si gnal
Data (R,G,B ) &
Control si gnal
In ter f a ce
TFT
Po w e r I n p u t
Power Input
Da t a I n p u t
Da t a I n p u t
V
COM
Liquid
Crystal
V
COM

Other manuals for LG 26LD350

Related product manuals