4.5. Auto Download
1) Press Adj. key on the Adj. Remote control.
2) Select EDID D/L menu.
3) By pressing Enter key, EDID download will begin
4) If Download is successful, OK is display, but If Download if
failure, NG is displayed.
5) If Download is failure, Re-try downloads.
* Edid data and Model option download (RS232)
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Never connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2
1) HD RGB EDID data
2) HD HDMI EDID data
* Detail EDID Options are below
ⓐ Product ID
ⓑ Serial No: Controlled on production line.
ⓒ Month, Year: Controlled on production line:
ex) Monthly : ‘02’ -> ‘01’
Year : ‘2010’ -> ‘14’
ⓓ Model Name(Hex):
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
Model Name HEX EDID Table DDC Function
HD Model 0000 00 00 Analog/Digital
LGE Internal Use OnlyCopyright © 2010 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 13 -
MODEL MODEL NAME(HEX)
all 00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
D-sub to D-sub DVI-D to HDMI or HDMI to HDMI
For HDMI EDIDFor Analog EDID
INPUT MODEL NAME(HEX)
HDMI1 65030C001000011D
HDMI2 65030C002000011D
HDMI3 65030C003000011D
012 34 5 67 8 9 A BCD EF
00 00 FF FF FF FF FF FF 00 1E 6D a b
10 c 01036873 41780ACF74A3574CB023
20 09 48 4C A1 08 00 81 C0 61 40 45 40 31 40 01 01
30 01 01 01 01 01 01 66 21 50 B0 51 00 1B 30 40 70
40 36 00 7E 8A 42 00 00 1E 01 1D 00 72 51 D0 1E 20
50 6E 28 55 00 7E 8A 42 00 00 1E 00 00 00 FD 00 3A
60 3E 1F 46 10 00 0A 20 20 20 20 20 20 d
70 d 00 e
80 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
90 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
A0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
B0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
C0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
D0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
E0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
F0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
012 34 5 67 8 9 A BCD EF
00 00 FF FF FF FF FF FF 00 1E 6D a b
10 c 01 03 80 73 41 78 0A CF 74 A3 57 4C B0 23
20 09 48 4C A1 08 00 81 C0 61 40 45 40 31 40 01 01
30 01 01 01 01 01 01 66 21 50 B0 51 00 1B 30 40 70
40 36 00 7E 8A 42 00 00 1E 01 1D 00 72 51 D0 1E 20
50 6E 28 55 00 7E 8A 42 00 00 1E 00 00 00 FD 00 3A
60 3E 1F 46 10 00 0A 20 20 20 20 20 20 d
70 d 01 e
80 02 03 20 F1 4E 10 1F 84 13 05 14 03 02 12 20 21
90 22 15 01 26 15 07 50 09 57 07 f
A0 f 8018711C1620582C25007E8A4200
B0 00 9E 01 1D 00 80 51 D0 0C 20 40 80 35 00 7E 8A
C0 42 00 00 1E 8C 0A D0 8A 20 E0 2D 10 10 3E 96 00
D0 7E 8A 42 00 00 18 02 3A 80 18 71 38 2D 40 58 2C
E0 45 00 7E 8A 42 00 00 1E 01 1D 80 D0 72 1C 16 20
F0 10 2C 25 80 7E 8A 42 00 00 9E 00 00 00 00 00 D5
NO Item CMD1 CMD2 Data0
Enter Download A A 0 0 When transfer the ‘Mode In’,
download Mode ‘Mode In’ Carry the command.
EDID data Download A E 00 10 Automatically Download
and Model (The use of a internal pattern)
option download