5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
▪ Normal line
model: (normal line)LN5xxx, LA6xxx, LA7xxx, LA8xxx
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-2 281 290 297 310 322 342
2 3-5 280 288 296 308 321 340
3 6-9 279 287 295 307 320 339
4 10-19 277 284 293 304 318 336
5 20-35 275 280 291 300 316 332
6 36-49 273 277 289 297 314 329
7 50-79 271 275 287 295 312 327
8 80-119 270 274 286 294 311 326
9 Over 120 269 273 285 293 310 325
Aging chamber line
(Aging chamber) Model : LN5xxx, LA6xxx, LA7xxx, LA8xxx
Standard color coordi n a t e a n d temperat u r e u s i n g
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-5 280 288 296 308 321 340
2 6-10 276 283 292 303 317 335
3 11-20 273 278 289 298 314 330
4 21-30 270 275 286 295 311 327
5 31-40 267 272 283 292 308 324
6 41-50 266 270 282 290 307 322
7 51-80 265 269 281 289 306 321
8 81-119 264 267 280 287 305 319
9 Over 120 263 266 279 286 304 318
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
(3) Using DFT(Auto)
PC (for communication through RS-232C) -> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
ITEM DATA(Area Number) AREA
AREA OPTION1 0 USA
1 CANADA
2 MEXICO
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model Module
Tool
option1
Tool
option2
Tool
option3
Tool
option4
32LN5300-UB LGD 545 41478 37004 12031
47LN5400-UA LGD 1569 33286 37004 46847
55LN5400-UA LGD(POLA) 2065 33286 37004 40703
50LN5400-UA LGD 1825 33286 37004 48895
42LN5400-UA LGD 1313 33286 37004 36607
42LN5300-UB LGD 1313 41478 37004 03839
42LN5300-UB AUO 9505 41478 37004 03839
42LN5300-UB LGD(POLA) 1297 41478 37004 03839
39LN5300-UB CMI(POLA) 5137 41478 37004 03839
39LN5300-UB AUO(POLA) 9233 41478 37004 03839
32LN5300-UB CSOT(POLA) 4625 41478 37004 03839
32LN530B-UB LGD 545 45574 37004 03839
32LN530B-UB LGD(POLA) 545 45574 37004 03839
Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode