EasyManua.ls Logo

LG 32LN5300 - Securing the TV to a Wall (Optional); Tidying Cables

LG 32LN5300
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 14 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
▪ Normal line
model: (normal line)LN5xxx, LA6xxx, LA7xxx, LA8xxx
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-2 281 290 297 310 322 342
2 3-5 280 288 296 308 321 340
3 6-9 279 287 295 307 320 339
4 10-19 277 284 293 304 318 336
5 20-35 275 280 291 300 316 332
6 36-49 273 277 289 297 314 329
7 50-79 271 275 287 295 312 327
8 80-119 270 274 286 294 311 326
9 Over 120 269 273 285 293 310 325
Aging chamber line
(Aging chamber) Model : LN5xxx, LA6xxx, LA7xxx, LA8xxx
Standard color coordi n a t e a n d temperat u r e u s i n g
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-5 280 288 296 308 321 340
2 6-10 276 283 292 303 317 335
3 11-20 273 278 289 298 314 330
4 21-30 270 275 286 295 311 327
5 31-40 267 272 283 292 308 324
6 41-50 266 270 282 290 307 322
7 51-80 265 269 281 289 306 321
8 81-119 264 267 280 287 305 319
9 Over 120 263 266 279 286 304 318
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
(3) Using DFT(Auto)
PC (for communication through RS-232C) -> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
ITEM DATA(Area Number) AREA
AREA OPTION1 0 USA
1 CANADA
2 MEXICO
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model Module
Tool
option1
Tool
option2
Tool
option3
Tool
option4
32LN5300-UB LGD 545 41478 37004 12031
47LN5400-UA LGD 1569 33286 37004 46847
55LN5400-UA LGD(POLA) 2065 33286 37004 40703
50LN5400-UA LGD 1825 33286 37004 48895
42LN5400-UA LGD 1313 33286 37004 36607
42LN5300-UB LGD 1313 41478 37004 03839
42LN5300-UB AUO 9505 41478 37004 03839
42LN5300-UB LGD(POLA) 1297 41478 37004 03839
39LN5300-UB CMI(POLA) 5137 41478 37004 03839
39LN5300-UB AUO(POLA) 9233 41478 37004 03839
32LN5300-UB CSOT(POLA) 4625 41478 37004 03839
32LN530B-UB LGD 545 45574 37004 03839
32LN530B-UB LGD(POLA) 545 45574 37004 03839
Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode

Other manuals for LG 32LN5300