EasyManua.ls Logo

LG 39LN549C - EXTERNAL CONTROL Device SETUP; RS-232 C Setup; Type of Connector; D-Sub 9-Pin Male

LG 39LN549C
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
32
EXTERNAL CONTROL DEVICE SETUP
EXTERNAL CONTROL DEVICE SETUP
RS-232C Setup
Connect the RS-232C (serial port) input jack to an
external control device (such as a computer or an A/
V control system) to control the product’s functions
externally.
Connect the serial port of the control device to the RS-
232C jack on the product back panel.
RS-232C IN
(CONTROL & SERVICE)
RS-232C on this unit is intended to be used with
third party RS-232C control hardware and software.
The instructions below are provided to help with
programming software or to test functionality using
telenet software. RS-232C connection cables are
not supplied with the product..
NOTE
Type of Connector;
D-Sub 9-Pin Male
1 5
6 9
RS-232C IN
(CONTROL & SERVICE)
No. Pin name
1 No connection
2 RXD (Receive data)
3 TXD (Transmit data)
4 DTR (DTE side ready)
5 GND
6 DSR (DCE side ready)
7 RTS (Ready to send)
8 CTS (Clear to send)
9 No Connection