- 19 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Using CA-210 Equipment. (18 CH)
White Balance adjustment coordination and color temperature for
Edge LED
Color
Temperature
C50 13,000k K
X=0.269
(±0.002)
Y=0.273
(±0.002)
<Test signal>
Inner pattern
(204 Gray
80IRE)
0 9,300k K
X=0.285
(±0.002)
Y=0.293
(±0.002)
W50 6,500k K
X=0.313
(±0.002)
Y=0.329
(±0.002)
White Balance adjustment table
Color coordination is different according to heat run time.
LSxxxx, LM5xxx, LM6xxx, 42LM7xxx, AUO(65LM6200)
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-2 280 287 296 307 320 337
2 3-5 279 285 295 305 319 335
3 6-9 277 284 293 304 317 334
4 10-19 276 283 292 303 316 333
5 20-35 274 280 290 300 314 330
6 36-49 272 277 288 297 312 327
7 50-79 271 275 287 295 311 325
8 80-119 270 274 286 294 310 324
9 Over 120 269 273 285 293 309 323
47/55LM7xxx, 47/55LM8xxx, 47/55LM9xxx
H/R Time(Min)
Cool Medium Warm
x y x x y x
269 273 285 293 313 329
1 0-2 283 293 299 313 320 339
2 3-5 282 291 298 311 319 337
3 6-9 281 290 297 310 318 336
4 10-19 279 289 295 309 316 335
5 20-35 277 284 293 304 314 330
6 36-49 274 279 290 299 311 325
7 50-79 271 277 287 297 308 323
8 80-119 270 274 286 294 307 320
9 Over 120 269 273 285 293 306 319
5.3. EYE-Q function check
(1) Turn on TV
(2) Press EYE key of Adj. R/C
(3) Cover the Eye Q II sensor on the front of the using your
hand and wait for 6 seconds
(4) Confirm that R/G/B value is lower than 10 of the “Raw Data
(Sensor data, Back lignt )” . If after 6 seconds, R/G/B
value is not lower than 10, replace Eye Q II sensor
(5) Remove your hand from the Eye Q II sensor and wait for 6
seconds
(6) Confirm that “ok” pop up.
If change is not seen, replace Eye Q II sensor
5.4. Magic Motion remote controller Check
5.4.1 Test equipment
- RF-remote controller for check, IR-KEY-CODE remote
controller.
- Check AA battery before test. A recommendation is that a
tester change battery every lots.
5.4.2. Test
(1) Make pairing with TV set by pressing “Mute (START) key”
on RCU.
(2) Check a cursor on screen by pressing ‘ENTER” or “OK”
key of RCU
(3) Stop paring with TV set by pressing “VOL+ (STOP) key.