ENGLISH
31
7 [Brightness] (Command: k h)
► To adjust screen brightness. You can also adjust
brightness in the picture settings.
Transmission
[k][h][ ][Set ID][ ][Data][Cr]
Data Min : 00 to Max : 64
Ack
[h][ ][Set ID][ ][OK/NG][Data][x]
8 [Color] (Command: k i)
► To adjust the screen color. You can also adjust colour
in the picture settings.
Transmission
[k][i][ ][Set ID][ ][Data][Cr]
Data Min : 00 to Max : 64
Ack
[i][ ][Set ID][ ][OK/NG][Data][x]
9 [Tint] (Command: k j)
► To adjust the screen tint. You can also adjust colour
in the picture settings.
Transmission
[k][j][ ][Set ID][ ][Data][Cr]
Data Red : 00 to Green : 64
Ack
[j][ ][Set ID][ ][OK/NG][Data][x]
10
[Sharpness] (Command: k k)
► To adjust the screen sharpness. You can also adjust
sharpness in the picture settings.
Transmission
[k][k][ ][Set ID][ ][Data][Cr]
Data Min : 00 to Max : 32
Ack
[k][ ][Set ID][ ][OK/NG][Data][x]
11
OSD Select (Command: k l)
► To select OSD (On Screen Display) on/o when
controlling remotely.
Transmission
[k][l][ ][Set ID][ ][Data][Cr]
Data 00 : [O]
Data 01 : [On]
Ack
[l][ ][Set ID][ ][OK/NG][Data][x]
12
Remote Control Lock Mode (Command: k m)
► To lock the front panel controls on the signage and
remote control.
Transmission
[k][m][ ][Set ID][ ][Data][Cr]
Data 00 : [O]
Data 01 : [On]
Ack
[m][ ][Set ID][ ][OK/NG][Data][x]
* If you are not using the remote control, use this
mode. When main power is off & on (plug-off and
plug-in, after 20 - 30 seconds), external control lock is
released.
* In the standby mode (DC off by off timer or ‘ka’, ‘mc’
command), and if key operation is on, signage will
not turn on by power on key of IR & Local Key.
13
[Balance] (Command: k t)
► To adjust balance. You can also adjust balance in the
audio settings.
Transmission
[k][t][ ][Set ID][ ][Data][Cr]
Data Min : 00 to Max : 64
Ack
[t][ ][Set ID][ ][OK/NG][Data][x]
14
[Color Temperature] (Command: x u)
► To adjust colour temperature. You can also adjust
color temperature in the picture settings.
Transmission
[x][u][ ][Set ID][ ][Data][Cr]
Data Min : 00 to Max : 64
Ack
[u][ ][Set ID][ ][OK/NG][Data][x]