- 16 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
If internal pattern is not available, use RF input. In EZ Adj.
menu 6.White Balance, you can select one of 2 Test-pattern:
ON, OFF. Default is inner (ON). By selecting OFF, you can
adjust using RF signal in 216 Gray pattern.
Adj. condition and cautionary items
(1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to isolate
adj. area into dark surrounding.
(2) Probe location: Color Analyzer (CA-210) probe should be
within 10cm and perpendicular of the module surface (80°~
100°)
(3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked using no
signal or Full-white pattern.
4.4.6. Reference (White Balance Adj. coordinate and
color temperature)
▪ Luminance: 204 Gray
Standard color coordinate and temperature using CS-1000
(over 26 inch)
Mode
Coordinate
Temp uv
X Y
Cool 0.269 0.273 13,000K 0.0000
Medium 0.285 0.293 9,300K 0.0000
Warm 0.313 0.329 6,500K +0.0030
Standard color coordinate and temperature using CA-210(CH 18)
Mode
Coordinate
Temp uv
X Y
Cool 0.269±0.002 0.273±0.002 13,000K 0.0000
Medium 0.285±0.002 0.293±0.002 9,300K 0.0000
Warm 0.313±0.002 0.329±0.002 6,500K +0.0030
4.4.6.1 ALELF&EDGE LED&IOL White balance table
Edge LED module change color coordinate because of aging time
apply under the color coordinate table, for compensated aging time
Edge (LM860X)
GP4
Aging time
(Min)
Cool Medium Warm
X Y X Y X Y
269 273 285 293 313 329
1 0-2 283 293 299 313 320 339
2 3-5 282 291 298 311 319 337
3 6-9 281 290 297 310 318 336
4 10-19 279 289 295 309 316 335
5 20-35 277 284 293 304 314 330
6 36-49 274 279 290 299 311 325
7 50-79 271 277 287 297 308 323
8 80-149 270 274 286 294 307 320
9 Over 150 269 273 285 293 306 319
4.4.7 THX Adjustment (For US Models)
For THX models, White Balance 4 point automatic control can
be done through the below steps. (Warm axis)
(1) 100 IRE White Balance Adjustment done.
(2) Control Backlight so the Maximum brightness
*In case of 100 IRE adjustment, backlight target value is
125cd/m2.
(3) 4 Point gamma and W/B adjustment done.
* With the controlled maximum brightness, adjust the Gamma
2.2 (60, 40, and 20 IRE / do not adjust at 80 IRE)
*For 10 IRE, set R, G, B gain to 0, 0, and 0, respectively.
4.5. Option selection per country
4.5.1. Method
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu.
(2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is done
using +, - KEY
4.6. Tool Option Inspection
Method: Press Adj. key on the Adj. R/C, then select Tool option.
Model Tool 1 Tool 2 Tool 3 Tool 4 Tool 5 Tool 6 Tool 7
84LM9600-UA
33005 41026 29485 20527 23055 1302 63115
4.7. Local Dimming Inspection (Optional)
4.7.1. Edge models with local dimming
(1) Press TILT key of the Adj. R/C and check moving
patterns. The white window patterns moves from center-left
to center-right. If local dimming function does not work, the
top and bottom edge LED area shows not blinking
4.8. Ship-out mode check (In-stop)
After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
After final inspection, Always turn on the Mechanical S/W.