Operation Details
- 18 -
Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
5-1. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
• A point: The indoor pipe temperature to be less than B°C.
The indoor fan operates for minimum 10sec. even if the indoor pipe temperature falls lower than B°C.
Low(V)Stop(VI)
C˚C
Indoor Pipe Temp.
D˚C
22˚C
20˚C
Selecting Fan Speed(IV)
Low(II)Stop(I)
(Hot-Start Operating)
Heating Start
(Hot-Start Release Point)
Selecting Fan Speed(III)
During heating operation, the operating procedure of the indoor fan is as the following.
Step Indoor fan speed Pipe temp.
Off ≤22°C(Hot start operating)
Low ≥22°C
Selecting speed ≥C°C
Low ≤D°C
Off ≤20°C
Heat OFF Heat ON
Indoor Temp. Indoor Temp.
15°C
20°C
20°C
15°C
20°C
20°C
C°C 32°C 34°C 36°C 30°C 31°C 33°C
D°C 28°C 30°C 32°C 26°C 28°C 30°C
B°C 27°C 29°C 31°C - - -