INSTALLATION MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
www.lghvac.com
www.lg.com
Copyright © 2021 LG Electronics Inc. All Rights Reserved.
ENGLISH
LG SPLIT COMPACT DEDICATED OUTDOOR AIR SYSTEM(DOAS)
MFL71810402
Rev.00
Question and Answer IconNeed help?

Do you have a question about the LG ARND203DCR4 and is the answer not in the manual?

LG ARND203DCR4 Specifications

General IconGeneral
BrandLG
ModelARND203DCR4
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

DANGER

Instructions for immediate danger, potentially leading to death or serious injury if not avoided.

Cautions

Wiring

Operation

DANGER

Hazards during operation such as flooding, wet hands, or tampering with safety devices.

Product Overview

Split Compact DOAS Interior Components

Identifies and illustrates the main internal components of the DOAS unit.

Controller Overview

R410A Refrigerant

WARNING

Warning about refrigerant cylinder placement in direct sunlight.

Installation

Location Selection

Guidance on selecting an appropriate and safe installation location for the unit.

Roughing In the Indoor Unit

Piping Connection

Unit Piping

Refrigerant Safety

Safety guidelines and warnings regarding refrigerant handling and concentration limits.

Piping Materials and Handling

Guidelines for selecting, handling, and storing piping materials to ensure cleanliness.

Refrigerant Pipe Connections

Brazing

Emphasizes best practices for brazing to prevent contamination and ensure proper operation.

Refrigerant Piping Installation

Selection of Field-Supplied Piping Material

Guidelines for selecting appropriate piping materials based on codes and pressure ratings.

Refrigerant System Engineering and Allowable Pipe Length

Information on system design, pipe length limits, and potential issues.

Electrical Information

Separating Power Wiring and Communication Cables

Guidelines for physically separating power and communication cables to prevent interference.

Power Wiring / Communication Cable Connection

Terminal Connections

Instructions for making secure terminal connections for wiring.

Connecting the Power Wiring

Steps for connecting power wiring to the unit, emphasizing safety.

Power Supply / Power Wiring Specifications

WARNING

Safety warnings related to power wiring, grounding, and overcurrent protection.

Communication Cable Specifications

Requirements for communication cables between units, including shielding and length.

Communication Cable Connection

Connection Procedure

Step-by-step guide for connecting control and power wiring.

Example of Power Wiring and Communications Cable Schematic

Leak / Pressure Check and Evacuation

Leak / Pressure Check

Procedure for checking refrigerant piping for leaks using nitrogen pressure.

Leak / Pressure Check Procedure Steps

Step-by-step guide for performing leak and pressure checks.

Evacuation

Evacuation Procedure Steps

Detailed steps for evacuating the refrigerant system.

Charging Refrigerant

Refrigerant Charge Worksheet

Worksheet for calculating and recording refrigerant charge based on pipe length and CF.

Controller

Central Controller Setting

Main Control Board Terminal Connections

Main Status Screen

Main Menu Navigation

Software Update

Installation Checklist