    Alan Bruce DDSAug 4, 2025
    Why does my LG ARNU show a high pressure error at cooling?
    • A
      amanda03Aug 4, 2025
      If your LG Air Conditioner's outdoor fan shows a high-pressure error during cooling, it could be due to a motor failure or poor ventilation around the outdoor heat exchanger. First, turn off the outdoor units for a while and then check if the outdoor fan is working. Also, make sure there are no obstructions blocking airflow around the outdoor units.
  • O
    olsenlisaAug 8, 2025
    What to do if the outdoor EEV in my LG ARNU Air Conditioner has no operating sound at applying power?
    • J
      Justin WilsonAug 8, 2025
      If the outdoor EEV in your LG Air Conditioner isn't making any operating sounds when power is applied, the coil might have failed. Check the resistance between the terminals to diagnose this issue.
  • A
    Alexis HernandezAug 12, 2025
    Why does the compressor stop during running in my LG Air Conditioner?
    • M
      Matthew GarciaAug 12, 2025
      If your LG Air Conditioner's compressor stops while running, it might be due to motor insulation failure. Check the resistance between the terminals and the chassis.
  • D
    Dawn FitzgeraldAug 16, 2025
    What to do if my LG ARNU's outdoor EEV heating fails and defrosts frequently?
    • Y
      ysilvaAug 16, 2025
      If the outdoor EEV in your LG Air Conditioner is experiencing heating failure and causing frequent defrosting, it could be due to a bad connector contact. Inspect the connector to resolve this issue.
  • J
    James LynchAug 20, 2025
    What to do if LG ARNU's outdoor EEV heating fails and the outdoor heat exchanger part is frozen?
    • J
      James MolinaAug 21, 2025
      If your LG Air Conditioner's outdoor EEV is experiencing heating failure and the outdoor heat exchanger part is frozen, the EEV may be clogged. Service is necessary to resolve this issue.
  • J
    Jill CameronAug 25, 2025
    What to do if my LG ARNU's outdoor EEV has low pressure error or discharge temperature error?
    • K
      Kelly BakerAug 26, 2025
      If your LG Air Conditioner's outdoor EEV is showing a low-pressure error or discharge temperature error, it could be that the EEV is clogged. Service is necessary to resolve this issue.
  • T
    Theresa RussoAug 29, 2025
    How to troubleshoot a non-operating compressor in my LG Air Conditioner?
    • J
      Jerry SchmidtAug 29, 2025
      If the compressor in your LG Air Conditioner isn't operating, it could be due to broken motor insulation. Check the resistance between the terminals and the chassis.

Summary

Safety Precautions

Model Names

Indoor Unit Model Names

Lists various indoor unit model names and their specifications.

Outdoor Unit Model Names

Lists outdoor unit model names based on capacity and function.

External Appearance

Indoor Units External Appearance

Provides visual representations of different indoor unit types.

Outdoor Units External Appearance

Shows visual representations of various outdoor units by HP capacity.

Combination of Outdoor Units

Nomenclature

Indoor Unit Nomenclature

Details the coding system for indoor unit model names.

Outdoor Unit Nomenclature

Explains the coding system for outdoor unit model names.

Outdoor Units Information

Ceiling Cassette Indoor Units

Ceiling Cassette 1-Way Specifications

Detailed specifications for 1-way ceiling cassette indoor units.

Ceiling Cassette 2-Way Specifications

Detailed specifications for 2-way ceiling cassette indoor units.

Ceiling Cassette 4-Way Specifications

Detailed specifications for 4-way ceiling cassette indoor units.

Art Cool Series Indoor Units

Art Cool Type Specifications

Specifications, functions, dimensions, and diagrams for Art Cool type indoor units.

Art Cool Type (Wide) Specifications

Specifications, functions, dimensions, and diagrams for Art Cool Wide type indoor units.

Art Cool Type (Mirror) Specifications

Specifications, functions, dimensions, and diagrams for Art Cool Mirror type indoor units.

Ceiling Concealed Duct Indoor Units

Ceiling Concealed Duct Low Static Specifications

Specifications, functions, dimensions, and diagrams for low static ceiling concealed duct units.

Ceiling Concealed Duct Built-in Specifications

Specifications, functions, dimensions, and diagrams for built-in ceiling concealed duct units.

Ceiling Concealed Duct High Static Specifications

Specifications, functions, dimensions, and diagrams for high static ceiling concealed duct units.

Wall Mounted Indoor Units

Wall Mounted Type Specifications

Specifications, functions, dimensions, and diagrams for wall-mounted indoor units.

Convertible Type Indoor Units

Convertible Type Specifications

Specifications, functions, dimensions, and diagrams for convertible type indoor units.

Floor Standing Indoor Units

Floor Standing Type Specifications

Specifications, functions, dimensions, and diagrams for floor standing indoor units.

ARUV;ARUN Series Outdoor Units

Outdoor Unit Specifications

Detailed specifications for cooling-only and heat pump ARUV/ARUN series outdoor units.

Outdoor Unit Functions

Details on the functions and parts of 8-40HP outdoor units, including sensors and layout.

Outdoor Unit Dimensions

Dimensional drawings and specifications for various outdoor unit capacities (5-40HP).

Outdoor Unit Piping Diagrams

Refrigerant flow diagrams for cooling, heating, and defrost operations.

Outdoor Unit Wiring Diagrams

Wiring diagrams for main and sub outdoor units, detailing component connections.

Outdoor Unit Function Details

Explanation of basic, special, protection, and other control functions for outdoor units.

Outdoor Unit Test Run

Procedure for checking the system before test run and handling abnormal conditions.

Troubleshooting Guide

Phenomena from Main Component Failure

Lists common phenomena from main component failures and their causes/checks.

Checking Method for Key Components

Guides for checking key components like compressors, fan motors, and EEVs.

Self-diagnosis Function

Explains error indicators, causes, and self-diagnosis function for system failures.

Exploded Views

UW1 and UY2 Series Exploded Views

Exploded views for UW1 and UY2 main, sub, heat pump, and cooling models.

TE, TD, TJ, TL Models Exploded Views

Exploded views for TE, TD, TJ, and TL Standard and Plasma models.

BH, BG, BR, B1, B2, CE, CF Units Exploded Views

Exploded views for BH, BG, BR, B1, B2, CE, and CF indoor unit models.

SE1, S5, SP, VE, VJ Models Exploded Views

Exploded views for SE1, S5, SP, VE, and VJ indoor unit models.

LG ARNU Series Specifications

General IconGeneral
SeriesARNU
ControlRemote Control
Cooling Capacity9, 000 - 36, 000 BTU/h
Heating Capacity9, 000 - 36, 000 BTU/h
Operating Temperature (Cooling)18°C - 46°C
Power Supply220-240V, 50Hz
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model