EasyManua.ls Logo

LG ARNU093BHA2 User Manual

LG ARNU093BHA2
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
(Company)
(ProjectManager)
Tag#:
ARNU093BHA2
MultiV™Ducted(HighStatic)
Btu/hIndoorUnit
Performance:
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Outdoor
:
95°FDB
Indoor:
70°FDB
Outdoor
:
47°FDB/43°FWB
HeatingCapacity(Btu/h) 10,900
Electrical:
PowerSupply(V/Hz/Ø) 208230/60/1
Pi
p
in
g
:
Refrigerant:
Condensate:
StandardFeatures:
•LimitedWarrantywithLGCeredInstallaon
•TwoYearFunctionalPartsWarranty
ControlsFeatures:
•Autochangeover
(HeatRecoveryonly)
•Autooperaon
•Autorestart
•Childlock
•Dualthermistorcontrol
•Groupcontrol
•E.S.P.control
•Hotstart
•Selfdiagnoscs
•Sleepmode
•Timer(on/o)
•Weeklyschedule
•Sodry(dehumidicaon)
•Fanspeedcontrol
UnitData:
RefrigerantType R410A
RefrigerantControl
EEV
Fan:
Type Sirocco
Quantity
1
Motor/Drive
BrushlessDigitallyControlled/Direct
Notes:
PowerInput¹(W) 150
CondensateLine(in,OD)
1
AirflowRateH/M/L(CFM)
353/300/265
Enterin
g
MixedAir:
HeatingMin(°FDB) 59
TotalCoolingCapacity(Btu/h) 9,600
FactoryInstalledPump²
Yes
CoolingMax⁴(°FWB)
76
SoundPressure⁵dB(A)(H/M/L)
35/34/33
Filter
WashablePrefilter
ExternalStaticPressure⁶(inwg)
0.31
1.ThePowerInputisratedathighspeed.
2.Maximumliis27infromboomofunit.
3.Requiresa7Dayprogrammablecontroller.
4.SeeEngineeringManualforsensibleandlatentcapacies.
5.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
6.Factorysetasstandard.
7.Allcommunicaoncabletobeminimum18AWG,2conductor,stranded,shieldedandmust
complywithapplicablelocalandnationa lcode.
8.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
9.Thisunitcomeswithadrynitrogencharge.
10.Thisdataisrated0abovesealevel,with25ofrefrigerantlineperindoorunitanda0
leveldifferencebetweenoutdoorandindoorunits.Allcapacitiesarenetwithacombination
ratiobetween95105%.
11.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
9,600
O
p
tionalAccessories:
RatedAmps(A) 0.92
LiquidLine(in,OD)
1/4Flare
VaporLine(in,OD)
1/2Flare
NetUnitWeight(lbs)
59
ShippingWeight(lbs)
68
Page1of2VRFSBDF002US012D18
Forcontinualproductdevelopment,LGreservestheright tochangespecificationswithoutnotice.
LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lgvrf.com
WirelessHandheldRemoteController‐PQWRHDF0
7DayProgrammableController(Black)‐PQRCVSL0
SimpleControllerwithMode(Black)‐PQRCVCL0Q
SimpleControllerwithoutMode(Black)PQRCHCA0Q
DryContactUnit‐PQDSB1
WallMountedTemperatureSensor‐PQRSTA0
7DayProgrammableController(White)‐PQRCVSL0QW
SimpleControllerwithMode(White)‐PQRCVCL0QW
SimpleControllerwithoutMode(White)‐PQRCHCA0QW
DryContactUnit‐PQDSBC
³
Question and Answer IconNeed help?

Do you have a question about the LG ARNU093BHA2 and is the answer not in the manual?

LG ARNU093BHA2 Specifications

General IconGeneral
RefrigerantR410A
Noise Level (Outdoor)48 dB(A)
Coefficient of Performance (COP)3.8
Cooling Capacity9000 BTU/h
Power Supply220-240V, 50Hz
Operation Range (Heating)-15°C to 24°C

Summary

Product Specifications and Performance

Performance Metrics

Details the unit's cooling and heating capacities, along with power input requirements.

Electrical Requirements

Specifies the required power supply voltage, frequency, phase, and rated amperage.

Refrigerant Piping Sizes

Lists the required sizes for the liquid and vapor refrigerant lines (OD).

Condensate Management

Provides information on condensate line size and the availability of a factory installed pump.

Unit Data and Sound Levels

Contains essential unit data like refrigerant type, sound pressure levels, and weight.

Fan and Airflow Specifications

Details the fan type, motor drive, airflow rates, and external static pressure.

Features and Operation Details

Controls and Operational Features

Lists various operational modes and functions like auto changeover, diagnostics, and timers.

Standard Product Features

Highlights key product features including limited warranty and installation benefits.

Optional Accessories List

Available Accessories

Lists available optional accessories such as remote controllers and sensors.

Operating Environment Parameters

Entering Mixed Air Conditions

Specifies the maximum cooling and minimum heating temperature conditions for operation.

Important Notes and Disclaimers

Technical Notes and Conditions

Contains crucial notes regarding installation, performance, and operating conditions.

Dimensional Drawings and Measurements

Unit External Dimensions

Provides a detailed table of all external dimensions for the indoor unit.

Center of Gravity Location

Indicates the unit's center of gravity with specific coordinate values.

Related product manuals