36 Room Air Conditioner
Disassembly
Disassembly
Indoor Unit
WARNING:
Disconnect the unit from
power supply before making any
checks. Be sure the power switch is set
to "OFF"
1. To remove the Grille from the Chassis.
- Pull the grille bottom, the remove 2 securing screws.
- Lift the both lower parts of panel front.
- After pull down this panel a bit, separate connecting
wire with product.
2. To remove the Control Box.
- Before removing the control box, be sure to
disconnect the wires from PWB.
- Pull the cover control out from the control box
and disconnect other wires.
- Remove securing screws.
- Pull the control box out from the chassis carefully.
Step Motor Connectors
Sensor Connector
Comp Connector
4Way/Fan Connector
Motor
Connector
Power Connector
Power Connector
Comp Connector
Panel Front
Connector