2005 Product Data 79
9. Coefficient of Capacity Change
Model: 5K~24K Btu Cooling Only
Model: 5K~12K Btu Heat Pump
(A)
(A)
Indoor
Indoor
Outdoor
Outdoor
(A)
(A)
Indoor
Indoor
Outdoor
Outdoor
Classification
Height
(A)
The Coefficient of Capacity Change
Total Pipe Length(m)
5 7.5 10 12.5 15
- - - (0.94) (0.93)
- 0.97 0.96 (0.95) (0.94)
0.99 0.98 0.97 (0.96) (0.95)
1.0 0.99 0.98 (0.97) (0.96)
1.0 0.99 0.98 (0.97) (0.96)
0.99 0.98 0.97 (0.96) (0.95)
- 0.97 0.96 (0.95) (0.94)
- - - (0.94) (0.93)
10
7
5
0
0
5
7
10
Classification
Height
(A)
The Coefficient of Capacity Change
Total Pipe Length(m)
5 7.5 10 12.5 15
-- - - -
- 0.97 0.97 - -
0.99 0.98 0.97 - -
1.0 0.99 0.98 - -
1.0 0.99 0.98 - -
0.99 0.98 0.97 - -
- 0.97 0.97 - -
-- - - -
10
7
5
0
0
5
7
10
( )= 18~24K Btu Only