EasyManuals Logo

LG AS-W096E1G0 Service Manual

LG AS-W096E1G0
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Service Manual 41
Operation
While in heating mode operation in order to protect the evaporator pipe of the outdoor unit from freezing,
reversed to cooling cycle to defrost the evaporator pipe of the outdoor unit.
Defrosting control is available 50 minutes later since heating cycle started and the pipe temperature of out-
door unit reaches below -6°C.
Setting Freq.
Operating
Freq. of
Comp.
4-Way
EEV
Open step
Outdoor
FAN
Indoor
FAN
Pre-Heat
LED
Deice STEP
Fh
min
Minimum Time
of Heating
Main Deice time
Fh
min
Fh
min
ON
OFF
Setting
Speed
ON
Hot
Start
OFF
Hot
Starting
ON
OFF
OFF
0123456
Setting
Starting step
Setting
Freq.
Setting
Speed
Setting
Speed
Hi Speed
Defrosting control