Cooling Capacity (Ton) | 1 Ton |
---|---|
Refrigerant | R32 |
Type | Split Air Conditioner |
Cooling Capacity | 12000 BTU/h |
Power Supply | 220-240V, 50Hz |
Operating Temperature (Cooling) | 18°C to 43°C |
Noise Level (Outdoor) | 50 dB |
Explains the structure and components of the indoor unit model number.
Explains the structure and components of the outdoor unit model number.
Provides general safety warnings and symbol meanings for safe operation.
Crucial safety guidelines to follow during the installation process.
Lists and details various indoor unit models and their specifications.
Lists and details various outdoor unit models and their specifications.
Visual representation and identification of different indoor unit types.
Provides detailed dimensions for outdoor units AUUH488C, AUUH728C, and AUUH1008C.
Detailed technical specifications for various indoor unit types.
Detailed technical specifications for outdoor units.
Step-by-step installation guide for cassette type indoor units.
Guidelines for selecting location and space requirements for outdoor units.
Instructions for connecting pipes and electrical wiring.
Overview of main unit operational indicators and functions.
Detailed explanation of cooling, heating, and fuzzy mode operations.
Guides for operating various types of remote controllers (CST, Duct, Convertible).
Features and connection details for simple central control systems.
Overview, characteristics, and configurations of the deluxe central control system.
Schematic diagrams for electronic control devices of indoor units.
Wiring diagrams illustrating connections for outdoor units.
Piping diagrams for AUUH488C models (Duo, Trio, Quartet).
Piping diagrams for AUUH728C models (Duo, Trio, Quartet).
Piping diagrams for AUUH1008C models (Duo, Trio, Quartet).
Analysis of temperature difference and operating current for cycle issues.
Guides for troubleshooting common operational failures.
Troubleshooting steps for specific sensor and communication error codes.
Step-by-step guide for pumping down the system.
Procedure for evacuating refrigerant from the system.
Procedure for charging the system with refrigerant.
Explanation of functions like Auto Swing, Soft-Dry, Cooling, and Heating modes.
Basic control, compressor, EEV, fan, and reversing valve control logic.
Details on defrost control and oil equalization logic for compressors.
Exploded views and parts lists for various indoor unit chassis types.
Exploded views and parts lists for outdoor units AUUH488C, AUUH728C, AUUH1008C.