Error Code Description
LED 1
(Red)
LED 2
(Green)
Indoor
status
21 DC Peak(IPM Fault)
2times 1time
OFF
22 Max. CT(CT2)
2times 2times
OFF
23 DC Link Low Volt.
2times 3times
OFF
24 Pressure switch/Heater Sink.
2times 4times
OFF
26 DC Comp Position Error
2times 6times
OFF
27 PFC Fault Error
2times 7times
OFF
29 Comp Over Current
2times 9times
OFF
32 D-Pipe High(Inv.)
3times 2times
OFF
40 CT Sensor(Open/Short)
4times
0 OFF
41 Inv. D-Pipe Th Error(Open/Short)
4times 1time
OFF
43 High Pressure Sensor(Open/Short)
4times 3times
OFF
44 Outdoor air Th Error(Open/Short)
4times 4times
OFF
45 Cond. Middle Pipe Th Error(Open/Short)
4times 5times
OFF
46 Suction Pipe Th Error(Open/Short)
4times 6times
OFF
48 Cond. Out-Pipe Th Error(Open/Short)
4times 8time
OFF
51 Capacity over
5times 1times
OFF
53
Communication Error(Indoor ÷ Outdoor)
5times 3times
OFF
60 EEPROM Error(Outdoor)
6times
0 OFF
61 Cond. Middle Pipe High
6times 1times
OFF
62 Heatsink Error(High)
6times 2times
OFF
65 Heatsink Th Error(Open/Short)
6times 5times
OFF
67 BLDC motor fan lock(Outdoor)
6times 7times
OFF
If abnormal voltage is supplied, the protection circuits will turn off the product in order to prevent
the component damage. The product will automatically restart after 3 minutes.