6.7 Troubleshooting Outdoor Error
A2UW14GFA0 / A2UW16GFA0 / A3UW18GFA0 / A3UW21GFA0
Display
code
Title Cause of error Check point & Normal condition
21
High current into the
compressor
• Compressor blocked
• Disconnection/shortcircuit
inside compressor
• Over load operation
(Outdoor fan constraint,
screened, blocked)
• Burned parts inside PCB
• Check compressor constraint
• Check compressor wire open/short
• Check compressor insulation damage
• Check outdoor fan constraint / screened / flow
structure
• Check if IPM burned