Installation Manual 29
ENGLISH
Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent.
CAUTION
20mm
GN/YL
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
NORMAL CROSS-SECTIONAL AREA
Terminal Block of Outdoor Unit
1(L) 2(N) 1(L) 2(N) 3 1(L) 2(N) 3
Terminal Block of Indoor Unit
POWER INPUT
The power cord connected to the outdoor unit should be
complied with the following specifications (This equipment shall
be provided with a cord set complying with the national
regulation).
The connecting cable connected to the indoor and outdoor
unit should be complied with the following specifications
(This equipment shall be provided with a cord set complying
with the national regulation).
WARNING:
Make sure that the screws of the terminal are free from looseness.
Wiring Connection
MODEL 1 Phase
AUUW096D
[UU09W ULD]
1.5mm
2
AUUW126D
[UU12W ULD]
1.5mm
2
AUUW186D
[UU18W UED]
2.5mm
2
AUUW186D1
[UU18W UED1]
2.5mm
2