EasyManua.ls Logo

LG Flatron 795FT Plus (FB795E-UA) - Page 16

LG Flatron 795FT Plus (FB795E-UA)
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
Figure 1. Cable Connection
220
Monitor to be
adjusted
IBM
Compatible PC
PARALLEL PORT
Power inlet (required)
Power LED
ST Switch
Power Select Switch
(110V/220V)
Control Line
Not used
RS232C
PARALLEL
V-SYNC
POWER
ST
VGS
MONITOR
E
V-Sync On/Off Switch
(Switch must be ON.)
F
A
B
C
E
F
A
B
C
15
10
5
5
69
1
1
1
14
13
25
6
5V
5V
5V
4.7K
4.7K
4.7K
74LS06
74LS06
OFF ON
OFF
ON
11
VIDEO
SIGNAL
GENERATOR
11) Display color 15,0 box pattern(70x70mm) at mode 4.
12) DRIVE ADJ command.
13)Set B-DRIVE to 100(decimal) at DRIVE of the
alignment program.
14)Adjust R-DRIVE and G-DRIVE command to white
balance x=0.283 ± 0.003 and y=0.298 ± 0.003 on
the White Balance Meter with PC arrow keys.15)
Adjust SUB-CONTRAST command to 47±1FL of
the raster luminance.
15) Display color 15,0 full white patten at Mode 4.
16) COLOR ADJ. LUMINANCE ABL command.
17) Adjust ABL to 33 ± 1FL of the luminance.
18) Exit from the program.
6. Adjustment for Focus.
1)
Display H character in full screen at Mode 4.
2)
Adjust two Focus control on the FBT that focus
should be the best condition.

Related product manuals