4.7. DPM operation confirmation
- Check if Power LED Color and Power Consumption operate
as standard.
(1) Set Input to RGB and connect D-sub cable to set.
(2) Measurement Condition : 230V@ 50Hz (Analog)
(3) Confirm DPM operation at the state of screen without
Signal
4.8 DDC EDID Write
1) Connect D-sub Signal Cable to D-Sub Jack.
2) Connect DVI Signal Cable to DVI Jack.
3) Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
4) Check whether written EDID data is correct or not. (refer
to Product spec).
(2) EDID DATA
1) ANALOG DATA 128Byte
2) DIGITAL DATA 128Byte
4.9. HDCP SETTING
(High-Bandwidth Digital Contents Protection)
1) Connect D-sub Signal Cable to D-Sub Jack.
2) Input HDCP key with HDCP-key- in-program.
3) HDCP Key value is stored on EEPROM(AT24C64)
which is E00~F20 addresses of 0xBC~0xBE page.
4) AC off/ on and on HDCP button of MSPG925 and
confirm whether picture is displayed or not of using
MSPG925.
5) HDCP Key value is different among the sets.
4.10. Outgoing condition Configuration
1) After all function test., press IN-STOP Key by SVC
Remote controller. And Make Ship Condition.
2) When pressing IN-STOP key by SVC remocon, Green
and red LED are blinked alternatively. And then
Automatically turn off. (Must not AC power OFF during
blinking)
4.11. Internal pressure
- Confirm whether is nomal or not when between power
board's ac block and GND is impacked on 1.5kV(dc) or
2.2kV(dc) for one second.
4.12
Option data setting (SVC OSD setting)
* PAL Model
*Tool Option : M228WA-BMH(Change by Suffix) Tool Option 7682
*Area Option : M228WA-BMH(Change by Suffix)-Area Option Braz
4.13. Tool / Area option confirm
- If Tool option(7682)/Area option(Braz) is not, change the
Too option(7682)/Area option(Braz) value compulsorily.
- 15 -
Copyright 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
ADH ADL LEN
BC 00 128
BC 80 128
BE 00 33
M228WA-BZH REMARK
Resolution 2 WSXGA
Module 0
TV 0
AV 1
COMPONENT 1
PC-RGB 1
DVI 1
HDMI 0
No Item Condition Remark
1 2HR-OFF 1 0 : 2 Hour off option –OFF
1 : 2 Hour off option –ON
2 FACTORY-MODE 0 0 : EEPROM Write Protection On
1 : EEPROM Write Protection Off
3 CHANNEL-MUTE 1
RAM Delay
1 Clock Phase 7
2 DQS0 Phase 2
3 DQS1 Phase 2
4 DQS2 Phase 2
5 DQS3 Phase 2
Power Off History
1 Last Power 0
2 Remocon 0
3 Key 0
4 Sleep Timer 0
5 RS232 0
6 Off Timer 0
7 Auto Off 0
8 2Hour Off 0
9 Reset
ETC
1 DFC Control 1
2 Exit Key 0
3 PWM DIM 255
4 Dimming Ctl. 255
5 DEBUG ON 0
6 UART ON 3
7 AGC TAKEOVER 16
8 AGC EData 0
9 AGC Bdata 0
10 SOG Level 1