- 4 -
• If power is on, it will operate to charge capacitor (330µF/450WV) on controller and power relay will oper-
ate after about 2~5sec.
The final operating freq. of comp. is set the lowest freq. that limited outdoor temp., discharge pipe temp.,
target freq., owing to CT.
It will be changed the drive voltage of comp. according to operating frequency.
It is only operated in the heating operation mode except defrosting operation.
High speed/Low speed
Outdoor Unit
Power relay control
Comp. Freq. control
Overheatng. Protection(Powr module)
Freq. speed control(up/down speed)
V/F control
Total current control (over current protection)
DC peak current control
4 way valve control
Outdoor fan motor control
Discharge pipe temp. control