12. AUTO CALIBRATION
12.5 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the result window
will show correction values per every power level and gain code and the same measure is performed per every
frequency.
12.6 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
12.7 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table will be reset.
12.8 Target Power
29.5 dBm29.5 dBm29.5 dBmMax power
1909.8 MHz1880 MHz1850.2 MHzFrequency
810661512Channel
PCS 1900
29.5 dBm29.5 dBm29.5 dBmMax power
1784.8 MHz1747.6 MHz1710.2 MHzFrequency
885699512Channel
DCS1800
32.5 dBm32.5 dBm32.5 dBmMax power
914.8 MHz897.4 MHz880.2 MHzFrequency
12437975Channel
EGSM 900
32.5 dBm32.5 dBm32.5 dBmMax power
848.8 MHz836.8 MHz824.2 MHzFrequency
251191128Channel
GSM 850
HighMiddleLowDescriptionBAND