2-13. Failure Diagnosis Function
1. Failure diagnosis function is function to facilitate service when nonconforming matters affecting performance of product
during use of product.
2. In occurrence of failure, pressing the function adjustment button does not perform function and only alarm sound (Ding~) rings.
3. If nonconforming matters occurred are released during display of failure code, MICOM returns to the original state (Reset).
4. Failure code is displayed on the display part of setting temperature for the freezing room and the display part of setting
temperature for the cold storage room of LCD, which are placed at the display part of a refrigerator. All the LCD graphics
other than a failure code are turned off.
In display of the failure mode, all LEDs of setting temperature for freezing/ setting temperature for cold storage are turned
off (excluding Note1 and Note2).
MICOM FUNCTION
- 11 -
LOCK
EXPRESS FRZ
FRZ
TEMP
LOCK
UNLOCK
ON
OFF
3SECS
REF
TEMP
Failure Code
display Part
Basic type
(GR-A207)
: Normal Operation
1
2
3
4
5
6
7
8
9
Er FS
Er RS
Setting temperature
display (Note 2)
Er DS
Er dH
Er FF
Er CF
Er CO
Setting temperature
display (Note 1)
Failure code display part
Setting
temperature
for freezing
Setting
temperature for
cold storage
No. Item
Contents of failure
Freezer
Fan
Compressor
Stepping
motor damper
Defrost
Heater
M/C room
Fan
Product operation status in failure
Failure of freezer
sensor
Failure of refrigerator
sensor 1
Failure of refrigerator
sensor 2
Failure of frost
removal sensor
Poor of frost
removal
Failure of BLDC FAN
at freezing room
Failure of BLDC FAN
at machine room
Failure of
Communication
Failure of
Outside Sensor
Snapping or short-circuit of
freezer sensor
Snapping or short-circuit of
refrigerator sensor 1
Snapping or short-circuit of
refrigerator sensor 2
Snapping or short-circuit of frost
removal sensor
Snapping of frost removal heater
or temperature fuse, pull-out of
connector (indicated minimum 4
hours after failure occurs)
Poor motor, hooking of wires to
fan. Contact of structures to Fan.
Snapping or short-circuit of L/wire
(if there is no fan motor signal for
more than 60 seconds in
operation of fan motor
Connection between main PCB
and display PCB. Snapping or
short-circuit of L/wire.
Transmission between main PCB
and display PCB. Poor TR and
receiving part.
Snapping or short-circuit of outside
temperature perceiving sensor
Standard
RPM
Standard
RPM
Standard
RPM
Standard
RPM
Standard
RPM
OFF (check every
30 minutes)
Standard
RPM
Standard
RPM
OFF (check
every 30 minutes)
ON for 15minutes
OFF for 15minutes
No frost
removal
Open for 10munutes,
closing for 15 minutes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG GR-A207CTBA and is the answer not in the manual?

LG GR-A207CTBA Specifications

General IconGeneral
BrandLG
ModelGR-A207CTBA
CategoryRefrigerator
LanguageEnglish

Related product manuals