4. TROUBLE SHOOTING
GS290 Operational Description Revision B
LG Electronics 67/136 LGE Property
4.3 Charging trouble
Check Points
-Connection of TA (check TA voltage 4.8V)
-Charging Current Path component voltage drop
-Battery voltage
1 Charging method : CC-CV
2 Charger detect voltage : 4.0 V
3 Charging time : 2h 00m
4 Charging current : 645 mA
5 CV voltage : 4.2 V
6 Cutoff current : 105 mA
7 Full charge indication current (icon stop current) : 105 mA
8 Recharge voltage : 4.16 V
4.2V~3.74V 3.73V~3.65V 3.65V~3.59V 3.59V~3.35V
TP1
TP2