EasyManua.ls Logo

LG GX200 - Page 80

LG GX200
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-80-
4.9.3 Checking Flow
Charging will operate
properly ?
Start
Measure voltage
of TP5,TP6 status ?
YES
NO
YES
Re-soldering and
Change CPU(U401)
and
Try again
Check voltage of
TP2 status ?
Re-soldering and
Change F1101 and
Try again
NO
Measure voltage
of TP3, TP4 status ?
Re-soldering and
Change U801 and
Try again
NO
YES
Measure voltage
of TP5 status ?
NO
The battery may have problem,
Change new battery pack a
nd
Try again
YES
Check battery connector
and USB connector
are well?
Change battery
connector J801and
J1101 USB connector
NO
YES

Other manuals for LG GX200