LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 115 -
12. AUTO CALIBRATION
Figure 12.2.2 The top view of Test JIG
12.3 Test Jig Operation
Power Source Description
Power Supply Usually 4.0V
Table 12-2 Jig Power
Switch Number Name Description
Switch 1 ADI-REMOTE In ON state, phone is awaked. It is used ADI chipset.
Switch 2 TI-REMOTE In ON state, phone is awaked. It is used TI chipset.
Switch 3 VBAT Power is provided for phone from battery
Switch 4 PS Power is provided for phone from Power supply
Table 12-3 Jig DIP Switch
LED Number Name Description
LED 1 Power Power is provided for Test Jig
LED 2 TA Indicate charging state of the phone battery
LED 3 UART Indicate data transfer state through the UART port
LED 4 MON Indicate data transfer state through the MON port
Table 12-4 LED Description