Indoor Unit Installation
Installation Manual 17
ENGLISH
The wall you select should be strong and
solid enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping connections
must be done safely.
How to fix installation plate
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping Right rear piping
C
D
B
A
Ø70mm
(SR, ST, SU)
Left rear piping Right rear piping
B
A
D
C
Installation plate
(S3)
SR(12 kBtu/h) 0 40 20 40
ST(18 kBtu/h~24 kBtu/h) 105 0 210 0
SU(12 kBtu/h) 92 44 67 44
S3(18 kBtu/h~24 kBtu/h) 58 3 292 3
CHASSIS (Capacity)
Distance (mm)
ABCD