ENGLISH
êìëëäàâ üáõä
LG Concealed Duct
Air Conditioner
INSTALLATION MANUAL
LG
IMPORTANT
• Please read this installation manual completely before
installing the product.
• When the power cord is damaged, replacement work shall
be performed by authorized personnel only.
• Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
• Please retain this installation manual for future reference
after reading it thoroughly.
Question and Answer IconNeed help?

Do you have a question about the LG LB-H608RSS0 and is the answer not in the manual?

LG LB-H608RSS0 Specifications

General IconGeneral
TypeSplit System
Cooling Capacity5.8 kW
Heating Capacity6.5 kW
RefrigerantR410A
Power Supply220-240V, 50Hz
Operating Temperature (Cooling)18-43 °C

Summary

Safety Precautions

Installation Safety

Instructions for safe installation, including circuit breakers and grounding.

Operation Safety

Precautions for safe operation, avoiding flammable gases and wet hands.

Installation of Indoor, Outdoor Unit

Indoor Unit Location Selection

Conditions for selecting the best location for the indoor unit installation.

Outdoor Unit Location Selection

Criteria for choosing the optimal location for the outdoor unit.

Piping Length and Elevation Specifications

Table detailing pipe sizes, lengths, elevation limits, and refrigerant requirements.

Indoor Unit Installation: Suspension Bolt Method

How to install the indoor unit using suspension bolts and dimensions.

Indoor Unit Installation: Console Bolt Method

Method for installing the indoor unit using console bolts for drainage.

Ceiling Mounting Installation Procedure

Steps for selecting, drilling, and securing suspension bolts for ceiling mounting.

Unit Gradient and Drain Piping Caution

Importance of unit declination and drain piping for proper water drainage.

Refrigerant Piping Work

Steps for connecting refrigerant pipes, including bending and air purge.

Outdoor Unit Installation Location and Space

Selecting the outdoor unit location and required maintenance space.

Electrical Wiring Requirements

Requirements for electrical wiring, power source, and circuit breakers.

Indoor Unit Wiring Connection

Steps for connecting wires to the indoor unit's control board.

Outdoor Unit Wiring Connection

Procedures for connecting wires to the outdoor unit and earthing.

Connecting Pipes to the Indoor Unit

Piping Preparation and Burr Removal

Steps for cutting pipes and removing burrs before flaring.

Connecting Pipes to the Outdoor Unit

Connecting Cables between Indoor Unit and Outdoor Unit

Air Purging and Evacuation

E.S.P.(External Static Pressure) Setting

How to Set E.S.P?

Procedure for Changing RPM Setting

Step-by-step guide to adjust the External Static Pressure (E.S.P.) setting.

External Static Pressure & air Flow

Test Running