- 27 -
9-4 Poor cooling in Freezer compratment
No
1
Checking flow
Check the sensor resistance.
2 Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3 Open the freezer door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 23
indicates -4°F.
Result & SVC Action
Status
Windy
No windy
SVC Action
Go to the 4
Check the F Fan motor
4 Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
Result
40.5 ~ 38.5
30.5 ~ 28.5
23 ~ 21.5
17.5 ~ 16.5
13.5 ~ 12.5
10.5 ~ 9.5
8 ~7.5