EasyManua.ls Logo

LG LFC25765ST - Finalizing Water Line Setup

LG LFC25765ST
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 28 -
(1) to (2)
(3) to (4)
270 ~330
Other
270 ~330
Other
It’s normal
Change damper
It’s normal
Change damper
Test Point
Result SVC Action
9-5 Over cooling in Fresh food compartment
No
1
Checking flow
Check the sensor resistance.
2 Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3 Open the refrigerator door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
(1) To (2)
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38.5 ~ 36.5
30.5 ~ 29.5
24.5 ~ 23.5
20 ~ 19
16 ~15.5
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan
Check the damper
(Go to the 5)
4 Input Test 2 Mode and
Check the air flow.
(Push the button 1 time)
5 Check the damper resistance.
Status
Windy
No windy
SVC Action
Go to the 5
It’s normal
(1)(3)
(2)
(4)

Table of Contents

Other manuals for LG LFC25765ST

Related product manuals