MAINTENANCE 35
Performance Data Sheet
Models Number 5231JA2002A-S Use with replacementcartridge5231JA2002A
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system as specified in NSF/ANSI 42.
i System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine |
1
Taste and Odor and Nominal Particulate Class III.
Capacity: 500 gal (1,892 L)
NSF% reductionreq, or
Average InfluentChallenge Average Product Average % Max, permissibleproduct
Substance Influent Concentration,Unitsapplytoeach Water Reduction
Concentration row Concentration water concentration
NominalParticulateClassI
Particlesize: >0.5to < 1um 24,333 At least10,000particles/ml 915 96 >_85%
Chlorinetaste andodor
1.9 2.0mg/L_+10% 0.07 96.4 >_50%
ClassIII
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.89 Ipm)
Water Pressure 20-125 psi (138-862 kPa)
Water Temperature 36 °F - 100 °F (0.6 °C -37.8 °C)
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system.
Systems must be installed and operated in accordance with
manufacturer's recommended procedures and guidelines.
Warranty: See Warrant, Card for Details.
For a replacement cartridge or for service
contact your local dealer.
You can also visit our website; www.lg.com
or call 1-877-714-7486.
CAUTION
To reduce the risk of property damage due to water
leakage:
Read and follow. Use instructions before installation and
use of this system.
Install on COLD water lines only.
Comply with all state and local plumbing codes.
Install a pressure limiting device and water hammer
arrester for inlet water pressures exceeding 80 psi (552
kPa). Refer to Uniform Plumbing Code, Sections 608.2 and
609.10).
Never install or operate where inlet water pressure may
exceed 125 psi (862 kPa).
Protect filter from freezing. Remove filter in temperatures
below 33°F (0.6°C).
Replace cartridge at specified service interval. Cartridge
MUST be replaced at least every 12 months.