EasyManua.ls Logo

LG LFX31925 Series - Icemaker Production Problems; Slow Water Dispensing Issues; No Ice Dispensing Issues

LG LFX31925 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 45 -
10. Reference
After measure the values, you should put in the TPA again.
10-1 TEST MODE and Removing TPA
1. How to make TEST MODE
If you push the test button on the Main PCB, the refrigerator will be enter the TEST MODE.
2. How to remove Terminal Position Assurance (TPA)
*
1 time : Comp / Damper / All FAN on
(All things displayed)
*
2 times : Damper closed
(22 22 displayed)
*
3 times : Forced defrost mode
(33 33 displayed)
Main PCB
<AC TPA> <DC TPA>

Other manuals for LG LFX31925 Series

Related product manuals