EasyManua.ls Logo

LG LFXS30796 Series - Removing the Freezer Drawers

LG LFXS30796 Series
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © 2016 - 2017 LG Electronics Inc. All
rights reserved. Only training and service purposes.
- 18 -
3-22 CAUTION : Sealed System Repair
Before making a sealed system repair : Start with the power cord unplugged from the outlet. Plug in the power cord and
between 6 and 12 seconds after it has been pugged in, unplug it from the power source. this will allow both sides of the 3
way valve to be opened to allow for proper evacuation.
3-23 3 Way Valve Service
Whole picture of refrigerator
R-Evaporator
F-Evaporator
The 3 way valve has plastic parts inside, so always wrap
it with a wet cloth before servicing when using a torch.
1) Always replace the 3 way valve if there is a leak at any
one of the 3 tubes coming from it.
2) Service in replacement of valve (valve failure) Perform
service in the same method as above.
Note : To service sealed system, follow the directions in "3-22" and "3-23" above.Then service is the same as a single
evaporator system.
R-Evaporator
F-Evaporator
3 Way Valve
R-Evaporator
F-Evaporator
3 way valve
Freezer Room
(Refrigerator outlet)
Refrigerator Room
(Refrigerant outlet)
Drier slide
(Refrigerator inlet)

Other manuals for LG LFXS30796 Series