10-7 AC Motor ASSEMBLY
Function The motor in the door pushed the ice into the dispenser.
How to
Measure
< In-door Motor >
< In-door Motor >
Standard
Geared Motor
Test Points
(1) to (2)
Result
31.1 ~ 42.09
Cube Solenoid
Test Points
(1) to (3)
Result
31.1 ~ 42.09
Separate the
housing.
Measure the
resistance between
(1) and (2)
Check the resistance between connectors (In-door motor 1, 2) and
(In-door motor 1, 3). It means check whether or not applying an
Electric current. If there is resistance, it means the geared motor or
solenoid is not inferiority
(1)
(2)
(3)
(1)
1
2
Separate the
housing.
Measure the
resistance between
(1) and (3)
1
2