Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
MultiFInverterHeatPumpOutdoorUnit
DFS‐SB‐AD‐004‐US013A08
Performance:
LMU369HV
Capacity(Btu/h) 34,000
CoolingPowerInput(kW)
2.72
HeatingPowerInput(kW)
3.58
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB Indoor: 70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB Outdoor: 47°FDB/43°FWB
Electrical:
PowerSupply(V¹/Hz/Ø) 208‐230/60/1
MOP(A)
25
MCA(A)
16.8
CoolingRatedAmps(A)
18.6
HeatingRatedAmps(A)
19.0
Compressor(A)
12.1
FanMotor
A
0.55
Piping:
RefrigerantCharge(lbs) 7.72
LiquidLine(in,OD)
1/4(4Each)
VaporLine(in,OD)
3/8(4Each)
MaxTotalPiping(ft)²
246.1
MaxElevationbetweenODUandIDU(ft)
49.2
MaxElevationbetweenIDUandIDU(ft)
24.6
ControlsFeatures:
•Autooperaon
•Autorestartoperaon
•Defrost/Deicing
•Inverter(variable
speedcompressor)
•Lowambientoperaonto
14F(coolingmode)
•Restartdelay(3‐minutes)
•Selfdiagnosis
•Sostart
OperatingRange:
Cooling(°FDB) 14‐118
Heatin
(°FWB) 0‐64
UnitData:
RefrigerantType R410A
RefrigerantControl
EEV
SoundPressure(±3dB(A))²
57
NetUnitWeight(lbs)
209.4
ShippingWeight(lbs)
222.6
HeatExchangerCoating
GoldFin™
MaxNumberofIndoorUnits
4
Compressor:
Quantity 1
Type
Twin‐RotaryInverter
Oil/Type
FVC68D
Fan:
Type Propeller
Quantity
2
FanMotor/Drive
BrushlessDigitallyControlled/Direct
AirflowRate(CFM)
2,119
StandardFeatures:
•LimitedFiveYearCompressorWarranty
•LimitedTwoYearFunconalPartsWarranty
Notes:
MaxODUtoIDUPiping(ft) 82.0
PipingLength(noadd'lrefrigerant,ft)
98.4
CommunicationCable(No.xAWG)³
4X18
1.Acceptableoperangvoltage:187V‐253V.
2.Pipinglengthsareequivalent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Allcommu nicaoncabletobeminimum18AWG,2‐conductor,stranded,shieldedand
mustcomplywithapplicablelocalandnationalcode.
5.SeeEngineeringManualforsensibleandlatentcapacies.
6.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Thisdataisrated0abovesealevel,with24.6ofrefrigerantlineanda0level
differencebetweenoutdoorandindoorunits.Allcapacitiesarenetwithacombination
ratiobetween95–105%.
8.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
MinNumberofIndoorUnits 2
Forcontinualproductdevelopment,LGreservestheright tochangespecificationswithoutnotice.
LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
O
tionalAccessories:
PI‐485IntegrationBoard(PMNFP14A0)
ACSmartII(PQCSW320A1E)
ACEz(PQCSZ250S0)
MOP‐MaximumOvercurrentProtection MCA‐MinimumCircuitAmpacity
ODU‐OutdoorUnit IDU‐IndoorUnit
AWG‐AmericanWireGage
Page1of5