– 24 –
6.1 Installation of indoor, Outdoor Unit
1) Select the best location
¥LIndoor unit
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the air
circulation.
• The place where air circulation in the room will be
good.
• The place where drainage can be easily obtained.
• The place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the space indicated by arrows from the wall,
ceiling, fence, or the obstacles.
¥MOutdoor unit
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted.
• There should not be any animals or plants which
could be affected by discharged hot air.
• Ensure the space indicated by arrows from the wall,
ceiling, fence, or other obstacles.
¥NPiping length and the elevation.
6. INSTALLATION
MODEL
MAX. Piping
length
A (m)
5HP 30 25
MAX.
elevation
B (m)