¡Æ Cooling Mode with the Sleep Mode
ƒU The setting temperature will be raised by 1¡ 30minutes later and by 2¡ 1 hour later.
ƒU The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
¡Æ Heating Mode with the Sleep Mode.
ƒU The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
ƒ¡14ƒ¡
Intake Air temp.
COMP. ON
(SET TEMP.+0.5¡ )
COMP. OFF
(SET TEMP. -0.5¡ ) Morethan More than
3 minutes 3 minutes
INDOOR FAN Low Low Low Low Low
COMPRESSOR ON OFF ON OFF ON
Delay 3 minutes
30 minutes 30 minutes
1¡
1¡
Setting Temp. +3¡
(Compressor OFF)
Setting Temp.
(Compressor ON)
Indoor Fan Med. Med. Med. Med. Med. Med.
Compressor ON OFF ON OFF ON OFF
¢”
¢”
¢”
¢”