Loading...
5. Auto Operation
ƒU The operation procedure is as following.
ƒNIf initial mode is decided, that mode is continued without the room temperature changing.
ƒƒUU
Auto Operation for Cooling.
ƒ¡15ƒ¡
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode Heating Soft Dry Cooling
Operation Condition Intake-air Temperature Setting temperature Fan speed Air Direction Control
Over 26°C 25°C
Over 24°C~below 26°C Intake air -1.0°C
Over 22°C~below 24°C Intake air -0.5°C
Over 20°C~below 22°C Intake air temperature
below 20°C 20°C
Over 20°C~below 30°C Fuzzy control
below 20°C 20°C
Over 30°C 30°C
below 21¡
below
24¡
~
Over 24¡
Over
21¡
When Auto Operation
initial start
When Switch to
Auto Operation
Controlled
by Fuzzy logic
1/f rhythm
Intake-Air temp
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp.-0.5°C
(Compressor ON)
Indoor Fan
Compressor ON OFF ON OFF
Fuzzy Speed
¢”
¢”