2) Connection of Pipings
1. Remove the installation plate
Pull the two '
¡
' marked portion of bottom of the chas-
sis and pull the installation plate out of chassis.
2. Route the drain hose and the indoor tubing.
3. Insert the pipings, the connecting cables and
the drain pipe throught the piping hole on the
wall.
4. Connect the pipings and the indoor tubing, and
drain hose and drain pipe.
Don't connect the cable to the indoor unit.
Wrap the insulation material around the connecting
portion.
Glue up the connection portion of drain hose and
drain pipe.
ƒ¡30ƒ¡
For right rear piping
Pipe Size Torque
Liquid Side (1/4") 1.8kg·m
Gas Side (3/8") 4.2kg·m
Installation plate
pull
pull
Indoor unit tubing
Flare nut Pipings
Torque wrench
Spanner
Plastic Bands Insulation material
Drain Pipe
Drain Hose
Adhevsive
Outdoor
Piping
Indoor
Connecting cable & Drain pipe
(LS-P0760CL/P0760HL, LS-P0820CL, LS-P0960CL/P0960HL)