  • M
    Mariah MayAug 8, 2025
    Why does my LG LS-K1860HL have high suction pressure and temperature?
    • A
      Autumn GilbertAug 8, 2025
      If your LG Air Conditioner shows high suction pressure and temperature, this could be caused by a defective compressor or a defective 4-way reverse valve. In this situation, the current is low.
  • C
    Corey BrownAug 17, 2025
    Why does my LG LS-K1860HL have normal suction pressure and temperature, but high pressure does not quickly rise?
    • R
      rossangelicaAug 17, 2025
      If your LG Air Conditioner has normal suction pressure and temperature but the high pressure does not quickly rise at the beginning of operation, it could be due to an excessive amount of refrigerant.
  • M
    Madison CrossAug 28, 2025
    Why is the current low in my LG LS-K1860HL Air Conditioner?
    • R
      Rebecca HamiltonAug 28, 2025
      If the current is low in your LG Air Conditioner due to a defective compressor or a defective 4-way reverse valve, you should check the refrigeration cycle.

Summary

Functions

Indoor Unit Functions

Details the functions related to the indoor unit of the air conditioner.

Dimensions

Unit Dimensions

Displays dimensions for both indoor and outdoor units with diagrams.

Refrigeration Cycle Diagram

Cooling and Heating Models Diagram

Illustrates refrigeration cycles for cooling-only and cooling/heating models.

Wiring Diagram

Indoor Unit Wiring Diagrams

Wiring diagrams for various indoor unit models.

Outdoor Unit Wiring Diagrams

Wiring diagrams for various outdoor unit models.

Operation Details

Main Unit Functions and Indicators

Details the main functions and indicators of the air conditioner unit.

Display and Self-diagnosis Functions

Display Indicators and Self-Diagnosis

Describes display indicators and self-diagnosis functions like thermistor errors.

Installation Procedures

Installation and Piping Connections

Covers location selection, unit mounting, drilling, and piping connections.

Refrigerant Handling and Servicing

Air Purging, Evacuation, Charging

Procedures for purging air, evacuating, and charging refrigerant into the system.

Pumping Down and Re-air Purging

Steps for pumping down refrigerant and re-purging air during re-installation.

Troubleshooting Guides

Cycle Troubleshooting

Analyzes troubles based on temperature differences and refrigeration cycle checks.

Electronic Parts Troubleshooting

Guides for troubleshooting product operation, remote control, and component issues.

Electronic Control Device

Main P.W.B Assembly

Details the main printed wiring board assembly and its parts list.

Display Assembly

Information and part numbers for the display assembly.

Schematic Diagrams

Cooling Only Series Diagram

Provides the schematic diagram for cooling-only series models.

Heat Pump Series Diagram

Presents the schematic diagram for heat pump series models.

Exploded Views & Parts Lists

Indoor Unit Parts

Exploded view and parts list for the indoor unit.

Outdoor Unit Parts

Exploded view and parts list for the outdoor unit.