Submittal Data :
Job Name :
Purchaser :
Engineer :
Submitted To :
Submitted By :
Unit Designation : Schedule No.:
Location :
P.O. No. :
Architect :
Date :
For : Reference Approval Construction
Model No.:
LS120CE
9 5/8
30 5/16
4
5
0
10 27/32
1
3
/
3
2
2
1
5
/
1
6
20 13/32
30 5/16
1
0
1
/
2
1
1
7
/
3
2
9
5
/
8
2 7/32
3
1
5
/
1
6
LSN120CE
LSU120CE
Capacities :
Cooling
Outdoor Design Temp.(,DB/WB)
Cooling
SEER
EER
Indoor Unit :
Power Supply (V,Ph,Hz)
Maximum Fuse Size
Minimum Ampacity
Weight (lbs)
Sound (dB(A),H/M/L Cool)
Air Circulation (CFM)
Dehumidification (pts/hr)
Outdoor Unit :
Power Supply (V,Ph,Hz)
Maximum Fuse Size
Minimum Ampacity
Weight (lbs)
Sound (dB(A), High Cool)
Refrigerant Piping :
Maximum Length (ft)
Maximum Height Difference (ft)
Liquid Side (O.D)
Gas Side (O.D)
Standard Features :
Five Year Compressor Warranty
Two Year Functional Parts Warranty
R-410a Refrigerant
Triple Filter Air Purifying System
Chaos Swing Air Circulation
Jet Cool
TM
LCD Wireless Remote Controller
Auto Restart
24 Hour On/Off Timer
Built-in Low Ambient Control down to 0
Temperature Display on Indoor Unit
11,500 Btu/h
95/75
13
10
36V DC
Powered by
Outdoor Unit
20.5
41/36/34
330
3.0
115,1,60
20
10.5
72.8
48
50
25
1/4”
1/2”
Note :
LG Electronics USA 2006 SD-LS120CE-VER1
Question and Answer IconNeed help?

Do you have a question about the LG LS120CE and is the answer not in the manual?

LG LS120CE Specifications

General IconGeneral
BrandLG
ModelLS120CE
CategoryAir Conditioner
LanguageEnglish

Summary

Capacities

Cooling Capacity

Specifies the cooling output of the unit in BTU/h.

Outdoor Design Temperature

Defines the design temperature conditions (Dry Bulb/Wet Bulb) for outdoor operation.

SEER Rating

Seasonal Energy Efficiency Ratio.

EER Rating

Energy Efficiency Ratio.

Indoor Unit Specifications

Indoor Unit Power Supply

Voltage, phase, and frequency requirements for the indoor unit.

Indoor Unit Fuse and Ampacity

Maximum fuse size and minimum ampacity for the indoor unit.

Indoor Unit Weight and Sound

Weight in pounds and sound pressure levels (High/Medium/Low Cool).

Indoor Unit Air Circulation

Airflow rate in CFM and dehumidification capacity in pts/hr.

Outdoor Unit Specifications

Outdoor Unit Power Supply

Voltage, phase, and frequency requirements for the outdoor unit.

Outdoor Unit Fuse and Ampacity

Maximum fuse size and minimum ampacity for the outdoor unit.

Outdoor Unit Weight and Sound

Weight in pounds and sound pressure level (High Cool).

Refrigerant Piping

Refrigerant Piping Length

Maximum allowable length for refrigerant piping in feet.

Refrigerant Piping Height Difference

Maximum allowable height difference between indoor and outdoor units.

Refrigerant Piping Sizes

Diameter of the liquid and gas refrigerant lines.

Standard Features

Compressor and Parts Warranty

Details on the compressor and functional parts warranty duration.

Refrigerant Type

Specifies the type of refrigerant used.

Air Purifying System

Highlights the triple filter air purifying system.

Air Circulation and Control Features

Includes Chaos Swing, Jet Cool, Auto Restart, and low ambient control.

Timer and Display Features

Features 24-hour timer and temperature display on the indoor unit.

Related product manuals