EasyManua.ls Logo

LG LS181HSV3 User Manual

LG LS181HSV3
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
HighEfficiencySingleZoneInverter
LS181HSV3
Performance:
Capacity(Btu/h) 18,200
SEER
20.5
EER
12.6
Cooling:
Heating:
Capacity(Btu/h) 22,000
HSPF
9.7
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB Indoor: 70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB Outdoor: 47°FDB/43°FWB
Electrical:
MCA(A) 19
MOP(A)
25
Compressor(A)
14.6
FanMotor(A)
0.25
OutdoorUnit:
CoolingRatedAmps(A) 15.4
HeatingRatedAmps(A)
15.4
CoolingPowerInput(kW)
1.45
HeatingPowerInput(kW)
1.76
Piping:
LiquidLine(in,OD) 3/8
AdditionalRefrigerant(oz/ft)
0.38
MaxElevation(ft)
49.2
PipingLength(noadd'lrefrigerant,ft)
24.6
ControlsFeatures:
•24-Houron/offmer
•4-Wayautoswing
•Autochangeover
•Autorestart
•Built-inlowambientstandard,
downto14°F(coolingmode)
•Chaoswind
•CondensateSensor
Connection
•Energysaving
•Inverter(variablespeed
compressor)
Page1of2DFS-SB-AA-029-US013H23
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
PowerSupply(V¹/Hz/Ø) 208-230/60/1
VaporLine(in,OD)
5/8
MaxPipeLength(ft)²
98.4
OperatingRange:
OutdoorUnit:
Cooling(°FDB) 14-118
Heating(°FWB)
-4-75
Cooling(°FWB)
64-90
Heating(°FDB)
60-86
IndoorUnit:
UnitData:
RefrigerantType R410A
RefrigerantCharge(lbs)
3.97
Fan:
Notes:
1.Acceptableoperangvoltage:187V-253V.
2.Pipinglengthsareequivalent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Allcommunicaon/powercabletobeminimum18AWG,4-conductor,stranded,
shieldedandmustcomplywithapplicablelocalandnationalcode.
5.SeeEngineeringManualforsensibleandlatentcapacies.
6.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Theindoorunitcomeswithadryheliumcharge.
8.Thisdataisrated0abovesealevel,with24.6ofrefrigerantlineanda0level
differencebetweenoutdoorandindoorunits.
9.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
ODUType Propeller
IDUType
CrossFlow
Motor/Drive
BrushlessDigitallyControlled/Direct
Dehumidification(pts/hr)
5.5
RefrigerantControl
EEV
HeatExchangerCoating
GoldFin™
IDUSoundPressure(H/M/L)(±3dB(A))³
45/40/35
ODUSoundPressure(±3dB(A))³
53
ODUNetUnitWeight(lbs)
123
ODUShippingWeight(lbs)
131
IDUNetUnitWeight(lbs)
32
IDUShippingWeight(lbs)
41
FanSpeeds(Fan/Cooling/Heating)
6/6/6
Quantity(ODU+IDU)
1+1
IDUAirFlowH/M/L(CFM)
622/509/399
ODUMaxAirFlowRate(CFM)
2,119
IndoorUnit(IDU)-LSN181HSV3OutdoorUnit(ODU)-LSU181HSV3
O
p
tionalAccessories
(
soldse
p
aratel
y)
LGProgrammableThermostat-PREMTB10U
LowAmbientWindBaffle(Coolingoperationto0°F)-ZLABGP02A
PI485-PMNFP14A0
SEER-SeasonalEnergyEfficiencyRatio EER-EnergyEfficiencyRatio
HSPF-HeatingSeasonal PerformanceFactor
MOP-MaximumOvercurrentProtection MCA-MinimumCircuitAmpacity
•Jetcool/Jetheat
•3MHAFFilter
•Self-cleaningindoorcoil
•Sleepmode
•Coolingonlyfuncon
TotalPowerInput:
Question and Answer IconNeed help?

Do you have a question about the LG LS181HSV3 and is the answer not in the manual?

LG LS181HSV3 Specifications

General IconGeneral
TypeSplit System
Cooling Capacity18, 000 BTU
RefrigerantR410A
Heating Capacity19, 000 BTU
Operating Temperature (Heating)75°F

Summary

Product Performance and Specifications

Cooling and Heating Performance

Details cooling/heating capacity, SEER, EER, and HSPF ratings.

Electrical Specifications

Covers power supply, MOP, MCA, and rated amps for cooling and heating.

Piping Requirements

Specifies pipe sizes, additional refrigerant, max pipe length, and elevation.

Operating Temperature Ranges

Outlines acceptable outdoor unit operating temperatures for cooling and heating.

Unit Data

Includes refrigerant type, charge, sound pressure, and unit weights.

Fan and Airflow

Details fan type, speeds, airflow rates for indoor and outdoor units.

Controls and Features

Control Features

Lists features such as timers, auto swing, energy saving, and jet cool.

Optional Accessories

Information on available accessories like thermostats and wind baffles.

Outdoor Unit (ODU) Dimensions

ODU Dimensional Drawings

Provides detailed diagrams showing dimensions and connection points.

ODU Component Identification

Lists and labels key components of the outdoor unit for installation.

Indoor Unit (IDU) Dimensions

IDU Dimensional Drawings

Presents diagrams with measurements and installation guidance for the indoor unit.

IDU Component Identification

Identifies parts of the indoor unit, including the front panel and air grille.

Related product manuals