15) Refrigerator Lamp is not working
CHECKING FLOW RESULT & SERVICE ACTION
Reset Refrigerator.
Check the Refrigerator Door S/W activating
movement.
1
2
NO.
Check for any loose connection in Refrigerator
Door S/W.
5
Reconnect Door S/W and check voltage.
4
3
Result
Service Action
Tight
movement
Free
movement
Change Door S/W
Abnormal
Normal
Go to Step 2
Unplug connector from Door S/W, then check
between terminals.
Result
Service Action
Firmly plugged
Loose
Go to Step 4
AC Part
DC Part
Lever S/W
Service Action
Released
Go to Step 5
0 Ù
Other
Replace Door S/W
Pressed
Go to Step 5
OFF
Other
Replace Door S/W
AC Part
Lever S/W
Service Action
Released
Lamps
0~5 Vac
Other
OFF
Pressed
Explain to customer
(NOTE: Lamp must
be OFF)
Go to Step 6
110~127 Vac
Go to Step 5
0~5 Vac
Other
ON
Action
Go to Step 5
Replace Door S/W
Go to Step 6
- 102 -