- 81 -
3) Abnormal Refrigerator Sensor Error (2)
CHECKING FLOW RESULT & SERVICE ACTION
Check for a loose connection.
Result
Service Action
Firmly plugged
Loose
Go to Step 2
Unplug connector in CON 7 and check between
Gray to Gray as is shown in the picture.
Result
Service Action
0 Ù
OFF
Go to Step 3
Go to Step 4
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #2)
Go to Step 6
1
2
NO.
1) Remove Cover sensor.
2) Cut sensor and check resistance value.
3
Result
Service Action
0 Ù
OFF
Replace Product
Short
Open
Change Sensor